YH-801C Power Cord Plug Tester (For single and double ends)
l Japanese Panasonic 5.7” Touch Screen, FP0 series programmable control(PLC), France SLD high performance AC contactor
l If the Conduction, Polarity, Insulation, Internal HV and External H.V not pass, the screen will display the fault contents .
l This machine will buzz and Light warming when the goods was not pass, and the screen can be locked the fault contents, then press the reset button the tester should be release the alarm state.
l Statistical report and printer function, like The order number, quantity of order, quantity of NG goods, Quantity of Pass goods etc, will displays and print.
l Start mode: Auto/step switch
|
Main parameters
|
|
Range
|
Inspection of continuity and polarity, Grounding resistance, insulation, voltage between cords, exposed copper and relative length
|
|
Standard
|
In accordance with UL, VDE, BSI, SAA, T-MARK, KS, IRAM, CCC etc standards.
|
|
Line Type
|
Single-end: 2P non-polarity, 2P polarity, 3P non-polarity, 3P polarity
Double-end: 2P non-polarity, 2P parallel, 2P cross, 3P parallel, 3P cross
|
|
Testing time
|
Internal, external high voltage test time: 0.2-99.9S.
|
|
Wire sensitivity
|
≥10PF
|
Insulation voltage
|
|
|
Grounding resistance
|
AC3~10A constant current / 0.1~510 mΩ, AC10-30A constant current/ 0.1~120mΩ,
Open circuit voltage: ≤6V, Industry with a unique test clamp.
|
|
Time of grounding resistance
|
0.1ï½999.9S
|
|
Upper limit of grounding resistance
|
AC3ï½10A/0.1ï½510mï¼AC10ï½30A/0.1ï½120mï¼
|
|
Insulation resistance
|
2, 5, 20, 50, 100, 200MΩ±5%, Six stage of adjustable, 31/2 counts LED digital meter the insulation resistance at current.
|
|
Internal high voltage
|
AC 0~5KV±5% continuously adjust, 31/2 counts digital LED display the voltage at current
|
|
Leakage current
|
0.5, 1.0, 1.5, 2.0, 3.0, 5.0, 10, 20mA±5% six stage.
|
|
External high voltage
|
AC 0~6KV/1.5mA, 31/2 counts digital LED display the voltage at current.
|
|
Counting function
|
Auto counting function of qualified and unqualified products, continuity and polarity failï¼insulation fail, high voltage fail.
|
|
Eject function
|
Qualified products auto eject and mark
|
|
Deal with the NG goods
|
Selected manually or automatically loaded scissors, can be a timely manner adverse Ordnance Disposal
|
|
Working mode
|
Single-end, double-end working mode
|
|
Electricity/gas source
|
AC220V/50Hz/60Hz, 5A; ≤4Kgf/cm²
|
|
Test mold
|
6pcs (UL2P/3P, VDE2P 4.0/4.8, VDE 3P, CCC2P/3P, BSI etc.) also according to customer demand for make
|
|
Conductive sponge
|
5pcs
|
|